Send Message
Home ProductsNonionic Polyacrylamide

Coal Washing Cas 9003-05-8 PAM Non Ionic Polyacrylamide

I'm Online Chat Now

Coal Washing Cas 9003-05-8 PAM Non Ionic Polyacrylamide

Coal Washing Cas 9003-05-8 PAM Non Ionic Polyacrylamide
Coal Washing Cas 9003-05-8 PAM Non Ionic Polyacrylamide Coal Washing Cas 9003-05-8 PAM Non Ionic Polyacrylamide

Large Image :  Coal Washing Cas 9003-05-8 PAM Non Ionic Polyacrylamide

Product Details:
Place of Origin: China
Brand Name: Raitte
Certification: ISO
Model Number: NPAM
Payment & Shipping Terms:
Minimum Order Quantity: 5 Tons
Packaging Details: 25KGS/PE Bag or According to your requirements
Delivery Time: 15 Days
Payment Terms: L/C, D/A, D/P, T/T

Coal Washing Cas 9003-05-8 PAM Non Ionic Polyacrylamide

Description
Solid Content: ≥88% Application:: Coal Washing
Molecular Weight: 8-10(million) Appearance: White Powder
Type: Flocculant Viscosity:: >1000cps
Cas No.: 9003-05-8 Sample: Test Free
High Light:

Cas 9003-05-8

,

PAM Non Ionic Polyacrylamide

High Molecular Coal Washing Non ionic Polyacrylamide PAM Cas No.9003-05-8

 

Non-ionic polyacrylamide of our company is produced on acrylamide by homopolymerization. High purity, good solubility. This product has received ISO9001 quality system certification.

1. It is mainly used for sludge dewatering,beneficiation, coal washing and separation of solid and liquid.
2. It can be used for disposal of industrial sewage and daily waste water.
3. It is excellent for paper making and oil field development.

 

 

Polyacrylamide:
Trade Name: Nonionic / Flocculant / Polyelectrolyte / Blufloc NPAM
Active Ingredient: High molecular weight polymer
Chemical Name: Nonionic Polyacrylamide / Polyelectrolyte / Flocculant
CAS No.: 9003-05-8
Standard: GB17514-2008
Brand: Blufloc
Certification: ISO, SGS
MOQ: 500kgs
Port of Loading: Shanghai Port, China
Delivery Time: Within 10 Working Days After Got Your Payment
Package: Packed in 25kgs kraft bag or white PE bag on pallet and 18-20ton/FCL, or 750kgs big bag
Applications: Water treatment, paper making, sludge dewatering, textile, sugar and juice, drilling, oil & gas, mining .
Sample: Free to test

 

Nonionic Polyacrylamide Application Fields

NO. Industry Application Area
1

Coal Mine

Washing

Coal washing tailing centrifugal separation

Sedimentation and filtration of coal powder and coal mud.

Highly improve the recovery rate of coal powder and the filtration speed.

2

Sewage Water

Treatment

Nonionic-polyacrylamide for acidophilic water systems.

If matched with PAC, aluminum sulphate, the effect will be excellent.

3

Metallurgical

Mineral Dressing

In floatation and smelting of Zinc, manganese and copper mines, its leachate and slag can be added into PAM to improve the separation efficiency.
4 Textile

Textile Sizing, as a kind of composition for chemical grout, starch textiles

Highly improve the adhesive property, penetrability and desizing performance,

enable the textile to have electrostatic prevention performance, reduces the

desizing rate, and reduces the starch mixing spots, cloth machine breaking

efficiency, and falling objects.

 

How to Use Polyacrylamide?

Application and Dosage:
The dosage range of varies from 0.2 - 3.0 ppm depending upon the type of effluent and application. It is always advised to do a jar test for evaluating the functioning and approximate dosage.
Jar Test:

Put sample of effluent in a beaker and add it as designated, agitate for 1 minute at 100-120 rpm and then slowly agitate at 60rpm. Determine the floc properly at this time and note the sedimentation and clarity of top solution.
Procedure and precautions upon dispersion and dissolving flocculants:
Dissolving time: The time required to dissolve the flocculant varies according to the type of flocculant, water quality, temperature and agitation. However, most flocculants generally require around 1 hour of agitation to completely dissolve the powder. Incomplete mixture of flocculant or lumping may inhibit the performance of the flocculant.
Agitation speed: The ideal revolution of the agitator is between 200-400rpm. A high speed agitator operating without reducing the revolution of a motor is not advised, since it may cut the molecules of the flocculant. An ideal agitator motor should be of 1HP for a 1-2m3 mixing tank.
Dissolving concentration: Flocculants should be standardly be dissolved to 0.1-0.2% concentration. It is also effective to start dissolving at a slightly higher concentration, and then dilute the flocculant mixture immediately before use.
Handling measures and precautions:
Proper human safety products such as Splash goggles, lab coat, vapor respirator, gloves and boots should be worn while handling and applying chemicals. Splashes on skin should be washed off with water immediately. In case of splashing into the eyes, flush it with fresh water and obtain medical attention. Should not be injected. Please refer MSDS for more details.

 

Coal Washing Cas 9003-05-8 PAM Non Ionic Polyacrylamide 0

Contact Details
Shandong Raitte Chemical Co., Ltd.

Contact Person: Evans Zhu

Tel: +86-13375585363

Fax: +86-532-80970818

Send your inquiry directly to us (0 / 3000)